• Login
    View Item 
    •   DSpace Home
    • School of Medicine
    • Journal Papers in Scopus 2
    • View Item
    •   DSpace Home
    • School of Medicine
    • Journal Papers in Scopus 2
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Viscoelastic Properties of Human Tracheal Tissues

    Thumbnail
    Date
    2017-01-01
    Author
    Farzaneh Safshekan
    Mohammad Tafazzoli-Shadpour
    Majid Abdouss
    Mohammad B. Shadmehr
    Metadata
    Show full item record
    Abstract
    © 2017 by ASME. The physiological performance of trachea is highly dependent on its mechanical behavior, and therefore, the mechanical properties of its components. Mechanical characterization of trachea is key to succeed in new treatments such as tissue engineering, which requires the utilization of scaffolds which are mechanically compatible with the native human trachea. In this study, after isolating human trachea samples from brain-dead cases and proper storage, we assessed the viscoelastic properties of tracheal cartilage, smooth muscle, and connective tissue based on stress relaxation tests (at 5% and 10% strains for cartilage and 20%, 30%, and 40% for smooth muscle and connective tissue). After investigation of viscoelastic linearity, constitutive models including Prony series for linear viscoelasticity and quasi-linear viscoelastic, modified superposition, and Schapery models for nonlinear viscoelasticity were fitted to the experimental data to find the best model for each tissue. We also investigated the effect of age on the viscoelastic behavior of tracheal tissues. Based on the results, all three tissues exhibited a (nonsignificant) decrease in relaxation rate with increasing the strain, indicating viscoelastic nonlinearity which was most evident for cartilage and with the least effect for connective tissue. The three-term Prony model was selected for describing the linear viscoelasticity. Among different models, the modified superposition model was best able to capture the relaxation behavior of the three tracheal components. We observed a general (but not significant) stiffening of tracheal cartilage and connective tissue with aging. No change in the stress relaxation percentage with aging was observed. The results of this study may be useful in the design and fabrication of tracheal tissue engineering scaffolds.
    DOI
    http://dx.doi.org/10.1115/1.4034651
    Collections
    • Journal Papers in Scopus 2

    Contact Us | Send Feedback
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Contact Us | Send Feedback