dc.description.abstractBackground: Detorquing value is an important factor in the amount of preload stresses during abutment screw fastening. This study evaluated the percentage of detorque values in two-piece machined titanium and premachined cast abutments in small diameter implants. Materials and Methods: Three groups of five samples were evaluated. Group 1 (G1), machined titanium abutments, group 2 (G2), premachined cast straight abutments that cast with gold-palladium, and group 3 (G3), premachined angled cast abutments that cast with the same alloy, were angled before casting. Each abutment was torque to 24Ncm according to the manufacturer's instructions and detorqued five times. The means of detorquing and torquing values in all groups were recorded. The mean of detorque in each group as a percentage of the toque value was calculated. The data for all groups were compared and calculated using analysis of variance (ANOVA) and t-test. Results: Mean detorque values in G1, G2, and G3 were 88.1±1.69, 93.1±2.68, and 80.9±4.95%, respectively. The ANOVA showed significant differences in mean of applied detorque (p < .001) and torque (p=.06) tightening among different groups. G2 had significantly greater detorque values (p < .05). No significant differences were found between G1 and G2. Surprisingly, abutment screw fracture occurred in three samples of G3. Conclusions: G3 showed significant percentage torque reduction (p < .05) and exhibited abutment screw fracture during evaluation. G2 presented the lowest torque reduction. Screw fracture occurred only in G3. © 2012 Wiley Periodicals, Inc.
dc.sourceClinical Implant Dentistry and Related Research
dc.subjectDetorque
dc.subjectImplant abutments
dc.subjectImplants
dc.subjectScrew fracture
dc.titleThe Effect of Repeated Torque in Small Diameter Implants with Machined and Premachined Abutments
dc.journal.volume14
dc.journal.issueSUPPL. 1
dc.identifier.doi10.1111/j.1708-8208.2012.00442.x
dc.journal.pages
dc.contributor.authorid55024740700
dc.contributor.authorid55027361400
dc.contributor.authorid54891622700
dc.contributor.citation55024740700|60018934|Abolfazl Saboury
dc.contributor.citation55027361400|60020449|Hamid Neshandar Asli
dc.contributor.citation54891622700|60018934|Shahram Vaziri
dc.contributor.affiliationid60018934
dc.contributor.affiliationid60020449
dc.contributor.affiliationid60018934


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record